Abbildung intAct Traktion-Power PzS
Symbol: Eignung für Battery-powered cleaning machines
Symbol: Eignung für Golf Caddey
Symbol: Eignung für forklift trucks
Symbol: Eignung für Lifting platforms
Symbol: Eignung für Electric wheelchairs
Symbol Recycling efficiency 95 %
Symbol Maximum tipping angle 45º
Closed lead-acid battery with armored plates | filled and charged | low maintenance

intAct Traktion-Power PzSFor the heaviest load

Since the active material here is "armored" in tubes, it can withstand the strongest cycles without loss of capacity. Ideal in multi-shift operation or for vehicles that need to be ready for use again after very short charging times.

Our recommendation for heavy duty applications with 1,000 cycles.

Features

  • Extremely robust

    Because of the tubular plates, this battery can withstand extremely many cycles.

    Your advantage: Especially long service life.

  • Easy to install

    Your benefit: Unproblematic battery replacement thanks to standardized battery boxes in common sizes for cars and trucks.

  • Low maintenance

    Here, the plugs can be removed and you can easily check. In addition, the truck sizes can be upgraded with a water filling system.

    Your advantage: easy prevention and maintenance, longer maintenance cycles.

Characteristics

  • For heavy professional cyclic use: 1,000 cycles according to IEC 254-1.
  • More cycle resistant for the same battery size compared to grid type plates.
  • Armored plate technology: Robust and technically mature for the heaviest loads.
  • Particularly vibration-resistant in uneven outdoor use. Tubes protect active material like an armor.
  • Long service life. Even in 2- to 3-shift operation. Durable, safe and reliable.
  • 6 and 12 volt versions.
  • Can be equipped with water filling system to extend service intervals.
  • Closed block battery with liquid electrolyte. Low maintenance.
Recycling efficiency 95 %
Maximum tipping angle 45º

All types

intAct Traktion-Power PzS

Battery Volt Capacity CCA Length mm Width mm Height mm Pos. of terminal Terminal
06TP175i6185 AH (c5), 240 AH (c20)26218128111more
product image Traction Battery intAct Traktion-Power PzS 06TP175

06TP175

Japan-Code:{jpn}

06TP175

Position of Terminal:1
Schema Schaltung 1
Volt:6
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:185 AH (c5), 240 AH (c20)
Base plate:none
Cold Cranking Ampere:
Size:262 x 181 x 281 mm
Schema Batteriekasten T02

Kasten: T02
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
06TP190i6190 AH (c5), 240 AH (c20)26218128111more
product image Traction Battery intAct Traktion-Power PzS 06TP190

06TP190

Japan-Code:{jpn}

06TP190

Position of Terminal:1
Schema Schaltung 1
Volt:6
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:190 AH (c5), 240 AH (c20)
Base plate:none
Cold Cranking Ampere:
Size:262 x 181 x 281 mm
Schema Batteriekasten T02

Kasten: T02
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
06TP210i6210 AH (c5), 270 AH (c20)24419027501more
product image Traction Battery intAct Traktion-Power PzS 06TP210

06TP210

Japan-Code:{jpn}

06TP210

Position of Terminal:0
Schema Schaltung 0
Volt:6
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:210 AH (c5), 270 AH (c20)
Base plate:none
Cold Cranking Ampere:
Size:244 x 190 x 275 mm
Schema Batteriekasten T01

Kasten: T01
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
06TP265i6265 AH (c5), 350 AH (c20)31218035901more
product image Traction Battery intAct Traktion-Power PzS 06TP265

06TP265

Japan-Code:{jpn}

06TP265

Position of Terminal:0
Schema Schaltung 0
Volt:6
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:265 AH (c5), 350 AH (c20)
Base plate:none
Cold Cranking Ampere:
Size:312 x 180 x 359 mm
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
06TP320i6320 AH (c5), 425 AH (c20)31218035901more
product image Traction Battery intAct Traktion-Power PzS 06TP320

06TP320

Japan-Code:{jpn}

06TP320

Position of Terminal:0
Schema Schaltung 0
Volt:6
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:320 AH (c5), 425 AH (c20)
Base plate:none
Cold Cranking Ampere:
Size:312 x 180 x 359 mm
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
12TP55i1255 AH (c5), 72 AH (c20)27817519001more
product image Traction Battery intAct Traktion-Power PzS 12TP55

12TP55

Japan-Code:{jpn}

12TP55

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:55 AH (c5), 72 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:
Size:278 x 175 x 190 mm
Schema Batteriekasten L03

Kasten: L03
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
12TP70i1275 AH (c5), 95 AH (c20)30417322001more
product image Traction Battery intAct Traktion-Power PzS 12TP70

12TP70

Japan-Code:{jpn}

12TP70

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:75 AH (c5), 95 AH (c20)
Base plate:none
Cold Cranking Ampere:
Size:304 x 173 x 220 mm
Schema Batteriekasten D31

Kasten: D31
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
12TP72i1272 AH (c5), 96 AH (c20)35317519001more
product image Traction Battery intAct Traktion-Power PzS 12TP72

12TP72

Japan-Code:{jpn}

12TP72

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:72 AH (c5), 96 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:
Size:353 x 175 x 190 mm
Schema Batteriekasten L05

Kasten: L05
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
12TP90i1290 AH (c5), 120 AH (c20)34917523901more
product image Traction Battery intAct Traktion-Power PzS 12TP90

12TP90

Japan-Code:{jpn}

12TP90

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:90 AH (c5), 120 AH (c20)
Base plate:none
Cold Cranking Ampere:
Size:349 x 175 x 239 mm
Schema Batteriekasten D02

Kasten: D02
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
12TP110i12110 AH (c5), 150 AH (c20)34917529001more
product image Traction Battery intAct Traktion-Power PzS 12TP110

12TP110

Japan-Code:{jpn}

12TP110

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:110 AH (c5), 150 AH (c20)
Base plate:none
Cold Cranking Ampere:
Size:349 x 175 x 290 mm
Schema Batteriekasten D03

Kasten: D03
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
12TP125i12125 AH (c5), 167 AH (c20)51017522541more
product image Traction Battery intAct Traktion-Power PzS 12TP125

12TP125

Japan-Code:{jpn}

12TP125

Position of Terminal:4
Schema Schaltung 4
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:125 AH (c5), 167 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:
Size:510 x 175 x 225 mm
Schema Batteriekasten DB10

Kasten: DB10
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
12TP150i12150 AH (c5), 200 AH (c20)51322322341more
product image Traction Battery intAct Traktion-Power PzS 12TP150

12TP150

Japan-Code:{jpn}

12TP150

Position of Terminal:4
Schema Schaltung 4
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:150 AH (c5), 200 AH (c20)
Base plate:none
Cold Cranking Ampere:
Size:513 x 223 x 223 mm
Schema Batteriekasten D05

Kasten: D05
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
12TP180i12180 AH (c5), 240 AH (c20)51827624241more
product image Traction Battery intAct Traktion-Power PzS 12TP180

12TP180

Japan-Code:{jpn}

12TP180

Position of Terminal:4
Schema Schaltung 4
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:180 AH (c5), 240 AH (c20)
Base plate:none
Cold Cranking Ampere:
Size:518 x 276 x 242 mm
Schema Batteriekasten D06

Kasten: D06
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet

Accessories
Charger

Fronius Selectiva


Battery-friendly high-performance chargers with high overall efficiency.


See product

Battery knowledge

SEALED BATTERY
BATTERY WATER
LOW-MAINTENANCE
Filling a dry pre-charged battery
Dry pre-charged batteries must be filled with battery acid and charged before installation.
First the format, then the capacity
A battery must of course fit in your vehicle, machine or device. Check the dimensions of your old battery or the available space where you want to install the battery. Check that the terminals are easily accessible, that you can reach them easily with …
Safety instructions for handling acid
Battery acid consists partly of sulphuric acid, which is highly corrosive. It attacks your skin, textiles and even metal. Put on protective clothing! So always wear gloves, safety glasses and possibly an acid-proof apron when handling batteries. Choose …
Avoid corrosion
The plates in a battery will corrode if they are not completely covered by battery water. Reasons for corrosion Sealing damaged before filling in dry pre-charged batteries Closed, low-maintenance batteries such as the intAct Bike-Power Classic are dry …
What does damage to the battery box indicate?
Damaged battery box If the housing is leaking, cracked or chafed, this indicates destruction by external influences. Tip: Look for a robust design in your next battery. Deformed battery case If the housing is deformed by heat, this indicates a defective …
What waterproof brings
Ideally, batteries should be kept dry. Even slight moisture can promote leakage currents. If you've noticed condensation on your battery frequently in the past, such as with temperature fluctuations, or water can get to your battery, it's worth considering …
Identifying and filling the liquid level
Markings on the outside of the white or transparent housing of a wet battery indicate the minimum (MIN) and maximum (MAX) fill levels. During commissioning or initial filling, the battery must be filled with battery acid up to the upper mark (MAX). During …
Why should you charge wet batteries open?
Gases are produced during charging. As they rise, they mix the battery acid. It is better for the battery if it is open during this process. Important: This only applies to initial charging and to all batteries that can be opened. Never open a battery by force!
Determine excessive self-discharge
If the battery charge drops significantly, possibly overnight, this may be due to leakage current. Silent, unwanted loads can be detected with an ammeter. Oils or liquids deposited on the surface of the battery can also cause considerable self-discharge. …
What does pole growth on the battery mean?
Whitish-grey deposits on the poles, so-called "pole growth", is caused by strong sulphation on the plates. Tip: Always ensure a good state of charge.
Drive batteries with armoured plates
Wet deep-cycle batteries in armoured plate or tubular plate technology are designed for the heaviest loads. Several tubes, in which the active mass is quasi "armoured", are joined together to form plates. This design makes them extremely resilient …

What is a traction battery?

Traction batteries supply power to the electric motor in machines and vehicles. They are designed to be charged with a charger when not in use and then discharged when in use. Traction batteries are designed for this repetitive alternation between charging and discharging or cycling. Unlike starter batteries, they tolerate being repeatedly discharged to a depth of discharge of up to 80 % well due to the special composition and construction of the grids and separators. The cycle stability of a traction battery provides information on how often it can reach this depth of discharge under ideal circumstances before it is damaged.

Maintenance and Care

In maintenance-free batteries, the electrolyte is in liquid form. They are usually closed at the factory, often with a double or labyrinth lid in which any gases produced condense and remain in the battery. In normal operation, maintenance-free ones do not lose any liquid. They cannot be opened, refilling is not possible and not necessary.

For which application is the intAct Traktion-Power PzS suitable?

Symbol Battery-powered cleaning machinesBattery-powered cleaning machines
Floor sweepers, floor washer-dryer machines, scrubber-dryer machines
Symbol Golf CaddeyGolf Caddey
Electric golf trolleys and/or golf caddies, Golf-Garts.
Symbol forklift trucksforklift trucks
forklift trucks, lift trucks, industrial trucks,
Symbol Lifting platformsLifting platforms
For electrically operated lifting platforms, scissor lifts, telescopic lifts, trailer lifts, mast lifts, vertical life
Symbol Electric wheelchairsElectric wheelchairs
Electric wheelchairs and electric mobiles