Abbildung intAct AGM-Power
Symbol: Eignung für Wohnmobile
Symbol: Eignung für Marine
Symbol: Eignung für wind-power plants
Symbol: Eignung für Solar applications
Symbol: Eignung für Bus
Symbol Recycling efficiency 95 %
Symbol Maximum tipping angle 90º
Sealed maintenance-free AGM battery with grid plates | electrolyte absorbed in glass fibre mats | wet charged

intAct AGM-PowerMaintenance-free all-round

Completely sealed maintenance-free and leak-proof, therefore well suited for the interior. Uncomplicated power supply for hobby and leisure-time pursuits and smaller solar applications.

Our recommendation for those looking for an affordable sealed supply battery.

Features

  • Leak-proof

    Because the electrolyte is bound in the glass fibre mat and the battery is tightly sealed and equipped with a safety valve, it is leak-proof.

    Your advantage: This battery is suitable for use on water, e.g. for powering on-board equipment or navigation instruments on boats, or wherever a leak-proof battery is required.

  • Maintenance-free

    Your advantage: You don't need to worry about water level checks and refills.

Characteristics

  • 300 charging cycles according to IEC 254-1.
  • Longer service life than flooded lead-acid battery.
  • Low self-discharge.
  • VRLA battery with gas recombination and safety valves, where refilling is neither possible or necessary.
  • Sealed AGM battery with grid plates.
  • Leak-proof. Can also be installed at an angle, as the electrolyte is absorbed in glass fibre mats and the battery is tightly sealed.
  • Wet charged. Ready to use.
  • Sealed maintenance-free.
Recycling efficiency 95 %
Maximum tipping angle 90º

All types

Battery Volt Capacity CCA Length mm Width mm Height mm Pos. of terminal Terminal
AGM55i1255 AH (c20), 70 AH (c100)24217519001more
product image Supply Battery intAct AGM-Power AGM55

AGM55

Japan-Code:{jpn}

AGM55

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:55 AH (c20), 70 AH (c100)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:
Size:242 x 175 x 190 mm
Schema Batteriekasten L02

Kasten: L02
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
AGM65i1265 AH (c20), 90 AH (c100)27817519001more
product image Supply Battery intAct AGM-Power AGM65

AGM65

Japan-Code:{jpn}

AGM65

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:65 AH (c20), 90 AH (c100)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:
Size:278 x 175 x 190 mm
Schema Batteriekasten L03

Kasten: L03
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
AGM90i1290 AH (c20), 110 AH (c100)35317519001more
product image Supply Battery intAct AGM-Power AGM90

AGM90

Japan-Code:{jpn}

AGM90

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:90 AH (c20), 110 AH (c100)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:
Size:353 x 175 x 190 mm
Schema Batteriekasten L05

Kasten: L05
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
AGM100i12100 AH (c20), 120 AH (c100)35817523301more
product image Supply Battery intAct AGM-Power AGM100

AGM100

Japan-Code:{jpn}

AGM100

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:100 AH (c20), 120 AH (c100)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:
Size:358 x 175 x 233 mm
Schema Batteriekasten T13

Kasten: T13
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
AGM130i12130 AH (c20), 150 AH (c100)51318922331more
product image Supply Battery intAct AGM-Power AGM130

AGM130

Japan-Code:{jpn}

AGM130

Position of Terminal:3
Schema Schaltung 3
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:130 AH (c20), 150 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:513 x 189 x 223 mm
Schema Batteriekasten D04

Kasten: D04
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
AGM180i12180 AH (c20), 200 AH (c100)51322322331more
product image Supply Battery intAct AGM-Power AGM180

AGM180

Japan-Code:{jpn}

AGM180

Position of Terminal:3
Schema Schaltung 3
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:180 AH (c20), 200 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:513 x 223 x 223 mm
Schema Batteriekasten D05

Kasten: D05
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
AGM200i12200 AH (c20), 230 AH (c100)51827624231more
product image Supply Battery intAct AGM-Power AGM200

AGM200

Japan-Code:{jpn}

AGM200

Position of Terminal:3
Schema Schaltung 3
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:200 AH (c20), 230 AH (c100)
Base plate:none
Cold Cranking Ampere:
Size:518 x 276 x 242 mm
Schema Batteriekasten D06

Kasten: D06
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet

Accessories
Charger

DEFA SmartCharge

Compact design for convenient charging of 12 volt batteries.


See product

Fronius Selectiva


Battery-friendly high-performance chargers with high overall efficiency.


See product

Battery knowledge

What is an AGM battery?
What is a camper battery?
A supply battery used in motorhomes or campers, colloquially known as a camper battery. Typically, it is charged with stationary charging current at the RV parking lot or via a solar system, because the alternator is not sufficient to provide the necessary …
What types of supply batteries are there?
In order to withstand the stress of cyclic operation for a long time without an excessive drop in performance, the active material in supply batteries is particularly well protected. Depending on the technology used, this is done in different ways: In …
Our absolutely maintenance-free motorcycle batteries
intAct Bike-Power AGM, intAct Bike-Power SLA, intAct Bike-Power GEL, intAct Bike-Power HVT and intAct Bike-Power GEL HVT-HD are valve regulated lead-acid batteries or VRLA batteries (VRLA=Valve Regulated Lead-Acid). VRLA batteries produce much less gas …
What does absolutely maintenance-free mean?
Absolutely maintenance-free batteries are valve-regulated lead-acid batteries or VRLA batteries (VRLA = Valve Regulated Lead-Acid) that are sealed at the factory. Here, significantly less gas is produced than in wet batteries. The gas produced remains …
Why does this battery have such a good current draw?
Due to the AGM technology, this battery absorbs the current particularly well, i.e. it recharges faster than a conventional wet battery and you can charge it with a higher charging current or a more powerful charger, like the ? This characteristic comes …
Pay attention to the state of charge
We recommend: Check the charge level every 2 - 3 months if ... ... the vehicle is often left unused. ... you drive a lot of short distances. ... many consumers are installed. ... it is cold. ... in start-stop systems the engine does not switch off as …
Every battery ages
With each charge/discharge process (cycle), active material is inevitably lost and the battery's performance declines. Once it has fallen to the point where it can no longer fulfil its purpose - e.g. start the vehicle, supply the consumers or drive the …
Avoid corrosion
The plates in a battery will corrode if they are not completely covered by battery water. Reasons for corrosion Sealing damaged before filling in dry pre-charged batteries Closed, low-maintenance batteries such as the intAct Bike-Power Classic are dry …
What is sulfation and what can you do about it?
Sulphation or sulphation is an undesirable ageing process in batteries where too much lead sulphate forms on the lead plates, which cannot be removed even with prolonged charging. The battery's capacity drops significantly, or it fails altogether. Sulfation …
What do deposits on the battery plugs mean?
Black deposits on the plugs indicate a battery that has worn out prematurely due to continuous excessive load. Tip: Always ensure a good balance between current drain and charging. Information on capacity calculations and charging behaviour can be found …
Batteries without vent hose
Only conventional, wet batteries need a vent hose, because they gas strongly during operation. The resulting steam can escape through the openings in the plugs. To prevent the vapour from damaging the vehicle, conventional batteries are vented to the …
Time for recovery
Before the winter or summer break, it is best to remove the battery or at least disconnect it and store it in a cool (ideally at 10 to 15 °C) and dry place. Charge every 4 to 6 weeks for 24 to 48 hours with a suitable charger. Check the state of charge …
What the battery does
In a nutshell, the battery generates electricity, which it delivers to the consumers. It is charged and is ready again. So far, so good. Meanwhile, a bit of chemistry happens inside the battery. Current flow In principle, current flows between a positive …
When liquid is lost
Fluid evaporates in batteries during the chemical reaction to generate electricity, more so in a wet battery than in an AGM or GEL battery where the acid is fixed in non-woven or as GEL respectively. Unlike these sealed batteries, the vapor in the sealed …
Always choose a battery that matches the load
Depending on the type of battery, it is designed for certain loads: Starter batteries must deliver as much current as possible during the starting process. The cold start current, measured in CCA, is informative here and shows how much starting power …

What is a Supply Battery?

Supply batteries must provide power for as long as possible for consumers that are not connected to the regular power grid or the starter battery. Either in mobile applications, e.g. camping or in island installations such as mountain huts, or in safety applications when the normal power grid fails or to compensate for so-called mains wipers. Depending on the application, they are charged with a charger from the mains or via smaller photovoltaic or wind power systems.

So not only do they have to supply power for a long time and then take it up again well, but they also have to cope well with changing current levels and voltages.

Supply batteries are cyclic batteries, i.e. they are designed to continuously deliver current up to a maximum depth of discharge of 80% when supplying electrical consumers and then to be fully recharged again. In contrast, a starter battery delivers a short, strong current surge for starting the engine and is recharged by the alternator while driving.

Maintenance and Care

Absolutely maintenance-free batteries are valve-regulated lead-acid batteries or VRLA batteries (VRLA = Valve Regulated Lead-Acid) that are sealed at the factory. Here, significantly less gas is produced than in wet batteries. The gas produced remains in the circuit of the battery due to gas recombination. As a result, these batteries lose significantly less liquid. They do not need to be topped up, and it is not even possible to do so, as they cannot be opened again without damage.

Für welchen Einsatz ist die intAct AGM-Power geeignet?

Symbol WohnmobileWohnmobile
Wohnmobile, Caravan, Motorcaravan, Motorhome, Campingbus, Reisemobil, Alkoven, Campingfahrzeuge
Symbol MarineMarine
Boats, ships, yachts
Symbol wind-power plantswind-power plants
As a power storage for small to medium-sized wind power plants or wind turbines.
Symbol Solar applicationsSolar applications
Small to medium-sized solar systems/solar applications e.g. in camping, stand-alone operation etc.
Symbol BusBus
Bus, Omnibus, Autobus