Maintenance-free calcium battery (Ca/Ca) with expanded metal grids | wet charged

intAct US-PowerFor American vehicles

State-of-the-art high-performance batteries, where dimensions and end-pole types are matched to the requirements of U.S. vehicles.

Our recommendation if installation dimensions and connections require a special battery.

Features

  • install

    Your advantage: Fits exactly into your US vehicle with the correct dimensions.

  • Connect quickly

    Your advantage: Can be easily connected to the cables of common US models using the US front terminal with internal thread or A-cone terminal.

Characteristics

  • Very high cold start performance.
  • Minimal self-discharge.
  • 2 versions: U.S. front pole with inside thread
    (Types 56010 and 57010) and A-cone pole according to DIN 60095 T2 (Type 58010).
  • Approval for charging voltages up to 14.8 volts.
    • Wet charged. Maintenance-free. Ready to use.
Recycling efficiency 95 %
Maximum tipping angle 45º

All Types

intAct US-Power

Battery Volt Capacity CCA Length mm Width mm Height mm Pos. of terminal Terminal
56010GUGi1260 AH (c20)600 A (EN)2301791861USmore
product image Starter Battery intAct US-Power 56010GUG

56010GUG

Japan-Code:{jpn}

56010GUG

Position of Terminal:1
Volt:12
Terminal:US
Capacity:60 AH (c20)
Base plate:B01
Cold Cranking Ampere:600 A (EN)
Size:230 x 179 x 186 mm


Kasten: G75
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
57010GUGi1270 AH (c20)670 A (EN)2601791861USmore
product image Starter Battery intAct US-Power 57010GUG

57010GUG

Japan-Code:{jpn}

57010GUG

Position of Terminal:1
Volt:12
Terminal:US
Capacity:70 AH (c20)
Base plate:B01
Cold Cranking Ampere:670 A (EN)
Size:260 x 179 x 186 mm


Kasten: G78
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
58010GUGi1285 AH (c20)800 A (EN)29518919211more
product image Starter Battery intAct US-Power 58010GUG

58010GUG

Japan-Code:{jpn}

58010GUG

Position of Terminal:1
Volt:12
Terminal:1
Capacity:85 AH (c20)
Base plate:B01
Cold Cranking Ampere:800 A (EN)
Size:295 x 189 x 192 mm


Kasten: G65
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet

Accessories
Charger

DEFA SmartCharge


Compact design for convenient charging of 12 volt batteries.


See product

Fronius Acctiva


Charge starter batteries professionally and supply consumers and on-board electronics.


See product
WHAT IS A WET BATTERY?
LOW-MAINTENANCE
MAINTENANCE FREE
Always choose the right battery for the application
When choosing a battery, it basically depends on what it is to be used for. The most important distinction is between starter batteries, including motorcycle batteries, and cyclic batteries such as traction or supply batteries. Starter batteries, including …
What is wear and what can you do about it?
With a worn battery, the active material has degraded due to excessive load. Modern vehicles with many consumers constantly place higher demands on the battery. The capacity of the installed batteries is often not designed for this. Prevention The choice …
Also important for starter batteries: the consumers
Even before the engine is started, the starter battery has to do a lot and supply standard equipment such as the lighting system. This draws current from the battery, which is no longer available for starting. Nowadays, there are also a number of consumers …
What the battery does
In a nutshell, the battery generates electricity, which it delivers to the consumers. It is charged and is ready again. So far, so good. Meanwhile, a bit of chemistry happens inside the battery. Current flow In principle, current flows between a positive …
What is a starter battery?
A battery that is charged by the alternator and starts the vehicle. For this purpose, the starter motor requires a lot of current for a short time. In addition to the cold start capacity (CCA), which indicates how much current the battery can ideally …
A coherent equation: A lot out, a lot in.
Every battery loses power over time. If it is loaded normally and is always fully charged, the capacity is slowly reduced. If it is often overloaded and insufficiently charged, the capacity is reduced much more quickly, i.e. the battery ages much faster. Ideally, …
What does maintenance-free mean?
In maintenance-free batteries, the electrolyte is in liquid form. They are usually closed at the factory, often with a double or labyrinth lid in which any gases produced condense and remain in the battery. In normal operation, maintenance-free ones do …
Checking the battery step by step
There are many reasons for weakening or failing batteries. An important step in tracking them down is to measure the voltage with a battery tester. Here's how: 1. preparation Disconnect the battery from the vehicle, if possible remove it. Tips on how …
Dry pre-charge battery before installation.
A battery that is not fully charged when installed will not reach its full performance in the future and will have a significantly shortened service life. Immediately after the first filling with acid, dry pre-charged batteries only reach 75 to 80 % of …
What is short circuit and how do I prevent it?
Short-circuiting occurs when the two terminals or plates of a battery are accidentally connected together. This can happen if the separator between the plates is damaged by vibration, for example, or if excessive battery sludge builds up, closing the …

What is a starter battery?

A battery that is charged by the alternator and starts the vehicle. For this purpose, the starter motor requires a lot of current for a short time. In addition to the cold start capacity (CCA), which indicates how much current the battery can ideally supply, the properties of a battery influence how reliably it can provide this starting power. A battery with very good charging properties recharges more quickly, for example, which benefits vehicles in city traffic in particular. It also supplies the consumers in vehicles without an additional back-up battery or supply battery. The more electrical consumers are installed at the factory or retrofitted, the more capacity is required to supply them when the vehicle is idling or at an engine stop and still reliably restart the vehicle.

Commissioning

A battery that is not fully charged when installed will not reach its full capacity in the future and will have a significantly shortened service life.

Even factory-filled and charged batteries can lose charge during storage. We recommend that you also fully charge them before installation.

You can find out how to do this in our step-by-step guide to charging your battery.

Maintenance and Care

In maintenance-free batteries, the electrolyte is in liquid form. They are usually closed at the factory, often with a double or labyrinth lid in which any gases produced condense and remain in the battery. In normal operation, maintenance-free ones do not lose any liquid. They cannot be opened, refilling is not possible and not necessary.

For which applications is the intAct US-Power suitable?

car
car, passenger car, cars, automobiles, vans, panel van