Abbildung intAct US-Power
Symbol: Eignung für car
Symbol Recycling efficiency 95 %
Symbol OEM quality
Symbol Maximum tipping angle 45º
Maintenance-free calcium battery (Ca/Ca) with expanded metal grids | wet charged

intAct US-PowerFor American vehicles

State-of-the-art high-performance batteries, where dimensions and end-pole types are matched to the requirements of U.S. vehicles.

Our recommendation if installation dimensions and connections require a special battery.

Features

  • install

    Your advantage: Fits exactly into your US vehicle with the correct dimensions.

  • Connect quickly

    Your advantage: Can be easily connected to the cables of common US models using the US front terminal with internal thread or A-cone terminal.

Characteristics

  • Very high cold start performance.
  • Minimal self-discharge.
  • 2 versions: U.S. front terminal with inside thread
    (Types 56010 and 57010) and A-cone terminal according to DIN 60095 T2 (Type 58010).
  • Approval for charging voltages up to 14.8 volts.
  • Wet charged. Maintenance-free. Ready to use.
Recycling efficiency 95 %
Start-Stop not
OEM quality
Maximum tipping angle 45º

All Types

intAct US-Power

Battery Volt Capacity CCA Length mm Width mm Height mm Pos. of terminal Terminal
56010GUGi1260 AH (c20)600 A (EN)2301791861USmore
product image Starter Battery intAct US-Power 56010GUG

56010GUG

Japan-Code:{jpn}

56010GUG

Position of Terminal:1
Schema Schaltung 1
Volt:12
Terminal:US
Schema Endpol USSchema Endpol US
Capacity:60 AH (c20)
Base plate:B01
Schema Bodenleiste B01Schema Bodenleiste B01
Cold Cranking Ampere:600 A (EN)
Size:230 x 179 x 186 mm
Schema Batteriekasten G75

Kasten: G75
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
57010GUGi1270 AH (c20)670 A (EN)2601791861USmore
product image Starter Battery intAct US-Power 57010GUG

57010GUG

Japan-Code:{jpn}

57010GUG

Position of Terminal:1
Schema Schaltung 1
Volt:12
Terminal:US
Schema Endpol USSchema Endpol US
Capacity:70 AH (c20)
Base plate:B01
Schema Bodenleiste B01Schema Bodenleiste B01
Cold Cranking Ampere:670 A (EN)
Size:260 x 179 x 186 mm
Schema Batteriekasten G78

Kasten: G78
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
58010GUGi1285 AH (c20)800 A (EN)29518919211more
product image Starter Battery intAct US-Power 58010GUG

58010GUG

Japan-Code:{jpn}

58010GUG

Position of Terminal:1
Schema Schaltung 1
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:85 AH (c20)
Base plate:B01
Schema Bodenleiste B01Schema Bodenleiste B01
Cold Cranking Ampere:800 A (EN)
Size:295 x 189 x 192 mm
Schema Batteriekasten G65

Kasten: G65
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet

Accessories
Charger

DEFA SmartCharge

Compact design for convenient charging of 12 volt batteries.


See product

Fronius Acctiva


Charge starter batteries professionally and supply consumers and on-board electronics.


See product
WHAT IS A WET BATTERY?
LOW-MAINTENANCE
MAINTENANCE FREE
Cleanliness pays off
To ensure proper battery function, it makes sense to keep the battery surface clean and dry. Greasy or silicone-containing dirt on the lid can hinder the flow of current. Moisture on the battery can cause a short circuit in the worst case.
Identifying and filling the liquid level
Markings on the outside of the white or transparent housing of a wet battery indicate the minimum (MIN) and maximum (MAX) fill levels. During commissioning or initial filling, the battery must be filled with battery acid up to the upper mark (MAX). During …
Checking the liquid level against sulphation
In a battery or accumulator, the chemical reaction between the active material of the grids and the acid generates current (electrons emitted) to supply the loads or stores current (electrons) provided by the charger or alternator. If the acid only partially …
Care should be taken when handling batteries
Chemical processes take place in batteries. They are influenced by external circumstances such as temperature or humidity. That is why it is worth taking care. During use, storage, installation and transport. For your own protection and for the protection …
What are car batteries?
For normal passenger cars, also US vehicles, Asian models and classic cars, mostly modern, maintenance-free flooded batteries are used, such as the intAct Start-Power NG, the intAct Race-Power or the intAct Premium-Power. These batteries are suitable …
Why should you charge wet batteries open?
Gases are produced during charging. As they rise, they mix the battery acid. It is better for the battery if it is open during this process. Important: This only applies to initial charging and to all batteries that can be opened. Never open a battery by force!
The difference between low maintenance, maintenance free and absolutely maintenance free.
Low-maintenance, flooded lead-acid batteries lose fluid during normal use. They must be maintained, i.e. the fluid level should be checked regularly and the fluid loss compensated with distilled water if necessary. These batteries usually have vent caps …
What the cold start performance says
Starter batteries primarily have to start the vehicle. To do this, they must deliver as much current as possible during the starting process, so the battery's high-current characteristics are important. The cold cranking amps (CCA) value provides information …
Do I need a start-stop battery or a normal one?
In start-stop vehicles, the engine stops every time the vehicle is in neutral. This saves petrol and reduces air pollution. However, this means an extremely high load for the battery. It has to start much more often, i.e. deliver high currents, than a …
Always choose a battery that matches the load
Depending on the type of battery, it is designed for certain loads: Starter batteries must deliver as much current as possible during the starting process. The cold start current, measured in CCA, is informative here and shows how much starting power …

What is a starter battery?

A battery that is charged by the alternator and starts the vehicle. For this purpose, the starter motor requires a lot of current for a short time. In addition to the cold start capacity (CCA), which indicates how much current the battery can ideally supply, the properties of a battery influence how reliably it can provide this starting power. A battery with very good charging properties recharges more quickly, for example, which benefits vehicles in city traffic in particular. It also supplies the consumers in vehicles without an additional back-up battery or supply battery. The more electrical consumers are installed at the factory or retrofitted, the more capacity is required to supply them when the vehicle is idling or at an engine stop and still reliably restart the vehicle.

Commissioning

A battery that is not fully charged when installed will not reach its full capacity in the future and will have a significantly shortened service life.

Even factory-filled and charged batteries can lose charge during storage. We recommend that you also fully charge them before installation.

You can find out how to do this in our step-by-step guide to charging your battery.

Maintenance and Care

In maintenance-free batteries, the electrolyte is in liquid form. They are usually closed at the factory, often with a double or labyrinth lid in which any gases produced condense and remain in the battery. In normal operation, maintenance-free ones do not lose any liquid. They cannot be opened, refilling is not possible and not necessary.

For which applications is the intAct US-Power suitable?

Symbol carcar
car, passenger car, cars, automobiles, vans, panel van