Abbildung intAct US-Power
Symbol: Eignung für car
Symbol Recycling efficiency 95 %
Symbol OEM quality
Symbol Maximum tipping angle 45º
Maintenance-free calcium battery (Ca/Ca) with expanded metal grids | wet charged

intAct US-PowerFor American vehicles

State-of-the-art high-performance batteries, where dimensions and end-pole types are matched to the requirements of U.S. vehicles.

Our recommendation if installation dimensions and connections require a special battery.

Features

  • install

    Your advantage: Fits exactly into your US vehicle with the correct dimensions.

  • Connect quickly

    Your advantage: Can be easily connected to the cables of common US models using the US front terminal with internal thread or A-cone terminal.

Characteristics

  • Very high cold start performance.
  • Minimal self-discharge.
  • 2 versions: U.S. front terminal with inside thread
    (Types 56010 and 57010) and A-cone terminal according to DIN 60095 T2 (Type 58010).
  • Approval for charging voltages up to 14.8 volts.
  • Wet charged. Maintenance-free. Ready to use.
Recycling efficiency 95 %
Start-Stop not
OEM quality
Maximum tipping angle 45º

All Types

intAct US-Power

Battery Volt Capacity CCA Length mm Width mm Height mm Pos. of terminal Terminal
56010GUGi1260 AH (c20)600 A (EN)2301791861USmore
product image Starter Battery intAct US-Power 56010GUG

56010GUG

Japan-Code:{jpn}

56010GUG

Position of Terminal:1
Schema Schaltung 1
Volt:12
Terminal:US
Schema Endpol USSchema Endpol US
Capacity:60 AH (c20)
Base plate:B01
Schema Bodenleiste B01Schema Bodenleiste B01
Cold Cranking Ampere:600 A (EN)
Size:230 x 179 x 186 mm
Schema Batteriekasten G75

Kasten: G75
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
57010GUGi1270 AH (c20)670 A (EN)2601791861USmore
product image Starter Battery intAct US-Power 57010GUG

57010GUG

Japan-Code:{jpn}

57010GUG

Position of Terminal:1
Schema Schaltung 1
Volt:12
Terminal:US
Schema Endpol USSchema Endpol US
Capacity:70 AH (c20)
Base plate:B01
Schema Bodenleiste B01Schema Bodenleiste B01
Cold Cranking Ampere:670 A (EN)
Size:260 x 179 x 186 mm
Schema Batteriekasten G78

Kasten: G78
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
58010GUGi1285 AH (c20)800 A (EN)29518919211more
product image Starter Battery intAct US-Power 58010GUG

58010GUG

Japan-Code:{jpn}

58010GUG

Position of Terminal:1
Schema Schaltung 1
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:85 AH (c20)
Base plate:B01
Schema Bodenleiste B01Schema Bodenleiste B01
Cold Cranking Ampere:800 A (EN)
Size:295 x 189 x 192 mm
Schema Batteriekasten G65

Kasten: G65
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet

Accessories
Charger

DEFA SmartCharge

Compact design for convenient charging of 12 volt batteries.


See product

Fronius Acctiva


Charge starter batteries professionally and supply consumers and on-board electronics.


See product
WHAT IS A WET BATTERY?
What the cold start performance says
Starter batteries primarily have to start the vehicle. To do this, they must deliver as much current as possible during the starting process, so the battery's high-current characteristics are important. The cold cranking amps (CCA) value provides information …
Charging correctly step by step
Tip: For full performance: Charge before first installation! 1. preparation Check that your charger matches the battery. Does the charger support the correct charging voltage? Does the charging current provided match the battery? What charging curve …
Caring for seasonally used starter batteries
Some batteries are only used seasonally - those in classic cars, motorcycles, boats, jet skis or snowmobiles, but also in certain utility, security or clearance vehicles. If a battery is installed in a vehicle that is not used for a long time, it will …
How does a melted pole occur?
A melted pole is caused by a short circuit when the battery polarity is reversed during bridging or when the poles are connected by a tool or other object. Tip: Take care when handling batteries. Learn more about short circuit and how to avoid it.
Pay attention to the state of charge
We recommend: Check the charge level every 2 - 3 months if ... ... the vehicle is often left unused. ... you drive a lot of short distances. ... many consumers are installed. ... it is cold. ... in start-stop systems the engine does not switch off as …
Our absolutely maintenance-free motorcycle batteries
intAct Bike-Power AGM, intAct Bike-Power SLA, intAct Bike-Power GEL, intAct Bike-Power HVT and intAct Bike-Power GEL HVT-HD are valve regulated lead-acid batteries or VRLA batteries (VRLA=Valve Regulated Lead-Acid). VRLA batteries produce much less gas …
What does absolutely maintenance-free mean?
Absolutely maintenance-free batteries are valve-regulated lead-acid batteries or VRLA batteries (VRLA = Valve Regulated Lead-Acid) that are sealed at the factory. Here, significantly less gas is produced than in wet batteries. The gas produced remains …
What do deposits on the battery plugs mean?
Black deposits on the plugs indicate a battery that has worn out prematurely due to continuous excessive load. Tip: Always ensure a good balance between current drain and charging. Information on capacity calculations and charging behaviour can be found …
What does maintenance-free mean?
In maintenance-free batteries, the electrolyte is in liquid form. They are usually closed at the factory, often with a double or labyrinth lid in which any gases produced condense and remain in the battery. In normal operation, maintenance-free ones do …
What is sulfation and what can you do about it?
Sulphation or sulphation is an undesirable ageing process in batteries where too much lead sulphate forms on the lead plates, which cannot be removed even with prolonged charging. The battery's capacity drops significantly, or it fails altogether. Sulfation …

What is a starter battery?

A battery that is charged by the alternator and starts the vehicle. For this purpose, the starter motor requires a lot of current for a short time. In addition to the cold start capacity (CCA), which indicates how much current the battery can ideally supply, the properties of a battery influence how reliably it can provide this starting power. A battery with very good charging properties recharges more quickly, for example, which benefits vehicles in city traffic in particular. It also supplies the consumers in vehicles without an additional back-up battery or supply battery. The more electrical consumers are installed at the factory or retrofitted, the more capacity is required to supply them when the vehicle is idling or at an engine stop and still reliably restart the vehicle.

Commissioning

A battery that is not fully charged when installed will not reach its full capacity in the future and will have a significantly shortened service life.

Even factory-filled and charged batteries can lose charge during storage. We recommend that you also fully charge them before installation.

You can find out how to do this in our step-by-step guide to charging your battery.

Maintenance and Care

In maintenance-free batteries, the electrolyte is in liquid form. They are usually closed at the factory, often with a double or labyrinth lid in which any gases produced condense and remain in the battery. In normal operation, maintenance-free ones do not lose any liquid. They cannot be opened, refilling is not possible and not necessary.

For which applications is the intAct US-Power suitable?

Symbol carcar
car, passenger car, cars, automobiles, vans, panel van