Sealed maintenance-free AGM battery | electrolyte absorbed in glass fibre mats | wet charged

intAct Start-Stop-Power AGM Start. Stop. Keep charging.

Enables a high number of engine starts and supplies all consumers when the motor stops. Perfect for taxis, medium and high-end cars, SUVs and trucks with start-stop systems and micro-hybrids with brake energy recovery (recuperation).

Our recommendation for start-stop vehicles with high energy demand and micro-hybrids with recuperation.

Features

  • Quick charging.

    Due to AGM technology, this battery charges particularly quickly. Ideal for cabs, also good for recuperation.
    Your advantage: This battery recharges quickly, even on short trips.

  • Frequent start

    A special grid shape provides
    higher cycle stability than a standard starter battery.
    **Your advantage: withstands the short charging times and frequent engine starts better than standard starter battery.

  • Much starting power

    As AGM with large reaction surface on the glass fiber fleece, this battery has a high starting power even partially discharged.
    Your advantage: Also suitable for vehicles with high power requirements (e.g. those with auxiliary heating).

Characteristics

  • Excellent starting characteristics even at low charge level.
  • Higher cycle stability and cold start performance than a standard starter battery of same case size. Resulting in a longer life expectancy.
  • Fantastic recharging behaviour in the partial charge range.
  • Also for vehicles with high energy requirements and/or a lot of additional equipment.
  • Double lid with safety valve (VRLA), gas recombination and backfire protection. Leak-proof.
  • Sealed AGM battery with lead-calcium-tin grids.
  • For start-stop vehicles and micro-hybrids with brake energy recovery (recuperation) and fuel-saving systems.
  • Absolutely maintenance-free battery, where refilling is neither possible nor necessary.
  • Can also be installed at an angle, as the electrolyte is absorbed in glass fibre mats and the battery is tightly sealed.
  • Wet charged. Ready to use.
Recycling efficiency 95 %
Start-Stop
Maximum tipping angle 90º

All Types

intAct Start-Stop-Power AGM

Battery Volt Capacity CCA Length mm Width mm Height mm Pos. of terminal Terminal
AGM50SSi1250 AH (c20)800 A (EN)26017320611more
product image Starter Battery intAct Start-Stop-Power AGM AGM50SS

AGM50SS

Japan-Code:{jpn}

AGM50SS

Position of Terminal:1
Volt:12
Terminal:1
Capacity:50 AH (c20)
Base plate:B07
Cold Cranking Ampere:800 A (EN)
Size:260 x 173 x 206 mm


Kasten: T12
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
AGM60SSi1260 AH (c20)680 A (EN)24217519001more
product image Starter Battery intAct Start-Stop-Power AGM AGM60SS

AGM60SS

Japan-Code:{jpn}

AGM60SS

Position of Terminal:0
Volt:12
Terminal:1
Capacity:60 AH (c20)
Base plate:B13
Cold Cranking Ampere:680 A (EN)
Size:242 x 175 x 190 mm


Kasten: L02
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
AGM70SSi1270 AH (c20)760 A (EN)27817519001more
product image Starter Battery intAct Start-Stop-Power AGM AGM70SS

AGM70SS

Japan-Code:{jpn}

AGM70SS

Position of Terminal:0
Volt:12
Terminal:1
Capacity:70 AH (c20)
Base plate:B13
Cold Cranking Ampere:760 A (EN)
Size:278 x 175 x 190 mm


Kasten: L03
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
AGM80SSi1280 AH (c20)800 A (EN)31517519001more
product image Starter Battery intAct Start-Stop-Power AGM AGM80SS

AGM80SS

Japan-Code:{jpn}

AGM80SS

Position of Terminal:0
Volt:12
Terminal:1
Capacity:80 AH (c20)
Base plate:B13
Cold Cranking Ampere:800 A (EN)
Size:315 x 175 x 190 mm


Kasten: L04
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
AGM95SSi1295 AH (c20)850 A (EN)35317519001more
product image Starter Battery intAct Start-Stop-Power AGM AGM95SS

AGM95SS

Japan-Code:{jpn}

AGM95SS

Position of Terminal:0
Volt:12
Terminal:1
Capacity:95 AH (c20)
Base plate:B13
Cold Cranking Ampere:850 A (EN)
Size:353 x 175 x 190 mm


Kasten: L05
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
AGM105SSi12105 AH (c20)950 A (EN)39417519001more
product image Starter Battery intAct Start-Stop-Power AGM AGM105SS

AGM105SS

Japan-Code:{jpn}

AGM105SS

Position of Terminal:0
Volt:12
Terminal:1
Capacity:105 AH (c20)
Base plate:B13
Cold Cranking Ampere:950 A (EN)
Size:394 x 175 x 190 mm


Kasten: L06
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet

Accessories
Charger

DEFA SmartCharge


Compact design for convenient charging of 12 volt batteries.


See product

Fronius Acctiva


Charge starter batteries professionally and supply consumers and on-board electronics.


See product
What is an AGM battery?
ABSOLUTELY MAINTENANCE-FREE
LEAK PROOF
DOUBLE LID WITH LABYRINTH
FIBERGLASS FLEECE
Do I need a start-stop battery or a normal one?
In start-stop vehicles, the engine stops every time the vehicle is in neutral. This saves petrol and reduces air pollution. However, this means an extremely high load for the battery. It has to start much more often, i.e. deliver high currents, than a …
Do I need an EFB or AGM start-stop battery?
If an EFB start-stop battery is installed at the factory, it can be replaced again with an EFB start-stop battery. An upgrade to AGM is always possible. If an AGM start-stop battery is installed at the factory, it may only be replaced with an AGM start-stop …
Our absolutely maintenance-free motorcycle batteries
intAct Bike-Power AGM, intAct Bike-Power SLA, intAct Bike-Power GEL, intAct Bike-Power HVT and intAct Bike-Power GEL HVT-HD are valve regulated lead-acid batteries or VRLA batteries (VRLA=Valve Regulated Lead-Acid). VRLA batteries produce much less gas …
What does absolutely maintenance-free mean?
Absolutely maintenance-free batteries are valve-regulated lead-acid batteries or VRLA batteries (VRLA = Valve Regulated Lead-Acid) that are sealed at the factory. Here, significantly less gas is produced than in wet batteries. The gas produced remains …
Why does this battery have such a good current draw?
Due to the AGM technology, this battery absorbs the current particularly well, i.e. it recharges faster than a conventional wet battery and you can charge it with a higher charging current or a more powerful charger, like the ? This characteristic comes …
What are start-stop batteries?
The EFB (Enhanced Flooded Battery) was developed for start-stop vehicles. This further development of the wet battery is significantly more cycle resistant, like the intAct Start-Stop-Power EFB. Because of the good current reserve, AGM batteries are also …
The order of disconnection and connection
The negative terminal is connected to the body, hence the name grounding. If you accidentally touch the positive terminal and the body at the same time when the negative terminal is connected, e.g. with a metallic tool, a short circuit could occur that …
Every battery ages
With each charge/discharge process (cycle), active material is inevitably lost and the battery's performance declines. Once it has fallen to the point where it can no longer fulfil its purpose - e.g. start the vehicle, supply the consumers or drive the …
Always select a battery that matches the charging behavior
Starter batteries, including motorcycle batteries, are charged by the alternator while driving. The charge takes place over a longer period of time with low current. Starter batteries are designed for this charging behaviour. Some starter batteries …
Cleanliness pays off
To ensure proper battery function, it makes sense to keep the battery surface clean and dry. Greasy or silicone-containing dirt on the lid can hinder the flow of current. Moisture on the battery can cause a short circuit in the worst case.
Filling a dry pre-charged battery
Dry pre-charged batteries must be filled with battery acid and charged before installation.
What is the point of vibration-proofing a starter battery?
Especially in trucks and other high-displacement commercial vehicles with diesel engines, there are strong vibrations that cause the battery to age prematurely. Our truck batteries in SHD versions are vibration resistant according to V3, like the intAct …
Checking the liquid level against sulphation
In a battery or accumulator, the chemical reaction between the active material of the grids and the acid generates current (electrons emitted) to supply the loads or stores current (electrons) provided by the charger or alternator. If the acid only partially …
What the cold start performance says
Starter batteries primarily have to start the vehicle. To do this, they must deliver as much current as possible during the starting process, so the battery's high-current characteristics are important. The cold cranking amps (CCA) value provides information …
Dimensions before starting power
First of all, a battery must fit in your vehicle or machine. Check the dimensions of your old battery or the available space in the battery compartment of your vehicle. The placement of the terminals, i.e. where exactly the positive and negative terminals …
Charging during long idle periods
If the vehicle is stationary for long periods and you make a lot of short journeys, it is advisable to charge the battery regularly with a charger, even if the battery has a low self-discharge rate or high cold-start performance. The exact intervals depend …

What is a starter battery?

A battery that is charged by the alternator and starts the vehicle. For this purpose, the starter motor requires a lot of current for a short time. In addition to the cold start capacity (CCA), which indicates how much current the battery can ideally supply, the properties of a battery influence how reliably it can provide this starting power. A battery with very good charging properties recharges more quickly, for example, which benefits vehicles in city traffic in particular. It also supplies the consumers in vehicles without an additional back-up battery or supply battery. The more electrical consumers are installed at the factory or retrofitted, the more capacity is required to supply them when the vehicle is idling or at an engine stop and still reliably restart the vehicle.

Commissioning

A battery that is not fully charged when installed will not reach its full capacity in the future and will have a significantly shortened service life.

Even factory-filled and charged batteries can lose charge during storage. We recommend that you also fully charge them before installation.

You can find out how to do this in our step-by-step guide to charging your battery.

Maintenance and Care

Absolutely maintenance-free batteries are valve-regulated lead-acid batteries or VRLA batteries (VRLA = Valve Regulated Lead-Acid) that are sealed at the factory. Here, significantly less gas is produced than in wet batteries. The gas produced remains in the circuit of the battery due to gas recombination. As a result, these batteries lose significantly less liquid. They do not need to be topped up, and it is not even possible to do so, as they cannot be opened again without damage.

For which applications is the intAct Start-Stop-Power AGM suitable?

car
car, passenger car, cars, automobiles, vans, panel van
Wohnmobile
Wohnmobile, Caravan, Motorcaravan, Motorhome, Campingbus, Reisemobil, Alkoven, Campingfahrzeuge
Marine
Boats, ships, yachts
hybrid vehicles
hybrid vehicles, hybrid cars, hybrid electric vehicles, hybrid electric vehicles
taxi vehicles
Start-Stop batteries for taxi vehicles with increased engine starts and long supply of the consumers when the engine is not running.