Abbildung intAct Race-Power
Symbol: Eignung für car
Symbol: Eignung für Tractors
Symbol: Eignung für Construction machinery
Symbol: Eignung für sitting lawn mowers
Symbol Recycling efficiency 95 %
Symbol OEM quality
Symbol Maximum tipping angle 45º
Maintenance-free calcium battery (Ca/Ca) | wet charged

intAct Race-PowerThe powerful all-rounder

Maintenance-free calcium battery, with good durability and excellent value for money. Increased performance compared to standard starter battery with same box size.

Our recommendation for a low-cost, high-performance starter battery for vehicles with more consumers.

Features

  • High starting currents

    Vehicles with additional consumers, e.g. electrical adjustment options or seat heating, need more current. With a special internal design, this battery delivers more power than a standard starter battery of the same box size.

    Your advantage: even if your vehicle needs a lot of starting power, you don't have to constantly recharge this battery.

  • Clean business

    A double lid provides increased leakage protection.

    Your advantage: The chance of the battery leaking is lower than with a battery with vent caps.

  • Price-conscious

    The long tested and proven technology enables us to offer excellent products at a reasonable price.

    Your advantage: an excellent price-performance ratio.

Characteristics

  • Increased performance of up to 15% above the EN standard due to the fully expanding the battery.
  • Wet charged. Ready to use.
  • Approved for charging voltage up to 14.8 volts.
  • Double lid for increased safety.
  • Maintenance-free.
Recycling efficiency 95 %
Start-Stop not
OEM quality
Maximum tipping angle 45º

All Types

intAct Race-Power

Battery Volt Capacity CCA Length mm Width mm Height mm Pos. of terminal Terminal
RP44i1244 AH (c20)420 A (EN)21017517501more
product image Starter Battery intAct Race-Power RP44

RP44

Japan-Code:{jpn}

RP44

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:44 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:420 A (EN)
Size:210 x 175 x 175 mm
Schema Batteriekasten LB1

Kasten: LB1
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
RP50i1250 AH (c20)450 A (EN)20717519001more
product image Starter Battery intAct Race-Power RP50

RP50

Japan-Code:{jpn}

RP50

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:50 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:450 A (EN)
Size:207 x 175 x 190 mm
Schema Batteriekasten L01

Kasten: L01
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
RP60i1260 AH (c20)540 A (EN)24217517501more
product image Starter Battery intAct Race-Power RP60

RP60

Japan-Code:{jpn}

RP60

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:60 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:540 A (EN)
Size:242 x 175 x 175 mm
Schema Batteriekasten LB2

Kasten: LB2
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
RP62i1262 AH (c20)540 A (EN)24217519001more
product image Starter Battery intAct Race-Power RP62

RP62

Japan-Code:{jpn}

RP62

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:62 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:540 A (EN)
Size:242 x 175 x 190 mm
Schema Batteriekasten L02

Kasten: L02
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
RP71i1271 AH (c20)670 A (EN)27817517501more
product image Starter Battery intAct Race-Power RP71

RP71

Japan-Code:{jpn}

RP71

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:71 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:670 A (EN)
Size:278 x 175 x 175 mm
Schema Batteriekasten LB3

Kasten: LB3
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
RP74i1274 AH (c20)680 A (EN)27817519001more
product image Starter Battery intAct Race-Power RP74

RP74

Japan-Code:{jpn}

RP74

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:74 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:680 A (EN)
Size:278 x 175 x 190 mm
Schema Batteriekasten L03

Kasten: L03
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
RP80i1280 AH (c20)700 A (EN)31517517501more
product image Starter Battery intAct Race-Power RP80

RP80

Japan-Code:{jpn}

RP80

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:80 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:700 A (EN)
Size:315 x 175 x 175 mm
Schema Batteriekasten LB4

Kasten: LB4
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
RP95i1295 AH (c20)800 A (EN)35317519001more
product image Starter Battery intAct Race-Power RP95

RP95

Japan-Code:{jpn}

RP95

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:95 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:800 A (EN)
Size:353 x 175 x 190 mm
Schema Batteriekasten L05

Kasten: L05
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet

Accessories
Charger

DEFA SmartCharge

Compact design for convenient charging of 12 volt batteries.


See product

Fronius Acctiva


Charge starter batteries professionally and supply consumers and on-board electronics.


See product
WHAT IS A WET BATTERY?
What does low maintenance mean?
Low-maintenance batteries can be recognised by the removable sealing plugs on the top, the vent hose and the white or transparent housing. In these batteries, the electrolyte is in liquid form, i.e. it is not bound as GEL or in fleece. They are not sealed …
Checking the liquid level against sulphation
In a battery or accumulator, the chemical reaction between the active material of the grids and the acid generates current (electrons emitted) to supply the loads or stores current (electrons) provided by the charger or alternator. If the acid only partially …
Every battery ages
With each charge/discharge process (cycle), active material is inevitably lost and the battery's performance declines. Once it has fallen to the point where it can no longer fulfil its purpose - e.g. start the vehicle, supply the consumers or drive the …
Chargers for rescue and safety vehicles
Emergency and rescue vehicles and other safety-related types of vehicles often sit around for months, but when it comes down to it, they need to be ready at a moment's notice to put out fires, rescue injured people or clear roads. Chargers like the Fronius …
Our absolutely maintenance-free motorcycle batteries
intAct Bike-Power AGM, intAct Bike-Power SLA, intAct Bike-Power GEL, intAct Bike-Power HVT and intAct Bike-Power GEL HVT-HD are valve regulated lead-acid batteries or VRLA batteries (VRLA=Valve Regulated Lead-Acid). VRLA batteries produce much less gas …
Knowledge
Depending on the type, this battery is low-maintenance or maintenance-free. Low maintenance version - TV types Low-maintenance batteries can be recognised by the removable sealing plugs on the top, the vent hose and the white or transparent housing. In …
What do deposits on the battery plugs mean?
Black deposits on the plugs indicate a battery that has worn out prematurely due to continuous excessive load. Tip: Always ensure a good balance between current drain and charging. Information on capacity calculations and charging behaviour can be found …
Identifying and filling the liquid level
Markings on the outside of the white or transparent housing of a wet battery indicate the minimum (MIN) and maximum (MAX) fill levels. During commissioning or initial filling, the battery must be filled with battery acid up to the upper mark (MAX). During …
Always choose a battery that matches the load
Depending on the type of battery, it is designed for certain loads: Starter batteries must deliver as much current as possible during the starting process. The cold start current, measured in CCA, is informative here and shows how much starting power …
For plugs: Simply open them and look inside.
Low maintenance batteries have a distinct advantage: if something is wrong, you can open them and look inside. What you see will give you some clues. Warning: You can tell if the battery can be opened by the individual plugs on the top. Often these lead-acid …

What is a starter battery?

A battery that is charged by the alternator and starts the vehicle. For this purpose, the starter motor requires a lot of current for a short time. In addition to the cold start capacity (CCA), which indicates how much current the battery can ideally supply, the properties of a battery influence how reliably it can provide this starting power. A battery with very good charging properties recharges more quickly, for example, which benefits vehicles in city traffic in particular. It also supplies the consumers in vehicles without an additional back-up battery or supply battery. The more electrical consumers are installed at the factory or retrofitted, the more capacity is required to supply them when the vehicle is idling or at an engine stop and still reliably restart the vehicle.

Commissioning

A battery that is not fully charged when installed will not reach its full capacity in the future and will have a significantly shortened service life.

Even factory-filled and charged batteries can lose charge during storage. We recommend that you also fully charge them before installation.

You can find out how to do this in our step-by-step guide to charging your battery.

Maintenance and Care

In maintenance-free batteries, the electrolyte is in liquid form. They are usually closed at the factory, often with a double or labyrinth lid in which any gases produced condense and remain in the battery. In normal operation, maintenance-free ones do not lose any liquid. They cannot be opened, refilling is not possible and not necessary.

For which applications is the intAct Race-Power suitable?

Symbol carcar
car, passenger car, cars, automobiles, vans, panel van
Symbol TractorsTractors
For tractors, tractors, axle tractors, tractors, bullodg, tractor tractors and implement carriers.
Symbol Construction machineryConstruction machinery
Compatible with construction machinery such as wheel loaders, tracked loaders, excavators and graders.
Symbol sitting lawn mowerssitting lawn mowers
sitting lawn mowers, lawn tractors