Abbildung intAct Race-Power
Symbol: Eignung für car
Symbol: Eignung für Tractors
Symbol: Eignung für Construction machinery
Symbol: Eignung für sitting lawn mowers
Symbol Recycling efficiency 95 %
Symbol OEM quality
Symbol Maximum tipping angle 45º
Maintenance-free calcium battery (Ca/Ca) | wet charged

intAct Race-PowerThe powerful all-rounder

Maintenance-free calcium battery, with good durability and excellent value for money. Increased performance compared to standard starter battery with same box size.

Our recommendation for a low-cost, high-performance starter battery for vehicles with more consumers.

Features

  • High starting currents

    Vehicles with additional consumers, e.g. electrical adjustment options or seat heating, need more current. With a special internal design, this battery delivers more power than a standard starter battery of the same box size.

    Your advantage: even if your vehicle needs a lot of starting power, you don't have to constantly recharge this battery.

  • Clean business

    A double lid provides increased leakage protection.

    Your advantage: The chance of the battery leaking is lower than with a battery with vent caps.

  • Price-conscious

    The long tested and proven technology enables us to offer excellent products at a reasonable price.

    Your advantage: an excellent price-performance ratio.

Characteristics

  • Increased performance of up to 15% above the EN standard due to the fully expanding the battery.
  • Wet charged. Ready to use.
  • Approved for charging voltage up to 14.8 volts.
  • Double lid for increased safety.
  • Maintenance-free.
Recycling efficiency 95 %
Start-Stop not
OEM quality
Maximum tipping angle 45º

All Types

intAct Race-Power

Battery Volt Capacity CCA Length mm Width mm Height mm Pos. of terminal Terminal
RP44i1244 AH (c20)420 A (EN)21017517501more
product image Starter Battery intAct Race-Power RP44

RP44

Japan-Code:{jpn}

RP44

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:44 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:420 A (EN)
Size:210 x 175 x 175 mm
Schema Batteriekasten LB1

Kasten: LB1
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
RP50i1250 AH (c20)450 A (EN)21017519001more
product image Starter Battery intAct Race-Power RP50

RP50

Japan-Code:{jpn}

RP50

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:50 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:450 A (EN)
Size:210 x 175 x 190 mm
Schema Batteriekasten L01

Kasten: L01
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
RP60i1260 AH (c20)540 A (EN)24217517501more
product image Starter Battery intAct Race-Power RP60

RP60

Japan-Code:{jpn}

RP60

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:60 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:540 A (EN)
Size:242 x 175 x 175 mm
Schema Batteriekasten LB2

Kasten: LB2
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
RP62i1262 AH (c20)540 A (EN)24217519001more
product image Starter Battery intAct Race-Power RP62

RP62

Japan-Code:{jpn}

RP62

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:62 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:540 A (EN)
Size:242 x 175 x 190 mm
Schema Batteriekasten L02

Kasten: L02
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
RP71i1271 AH (c20)670 A (EN)27817517501more
product image Starter Battery intAct Race-Power RP71

RP71

Japan-Code:{jpn}

RP71

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:71 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:670 A (EN)
Size:278 x 175 x 175 mm
Schema Batteriekasten LB3

Kasten: LB3
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
RP74i1274 AH (c20)680 A (EN)27817519001more
product image Starter Battery intAct Race-Power RP74

RP74

Japan-Code:{jpn}

RP74

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:74 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:680 A (EN)
Size:278 x 175 x 190 mm
Schema Batteriekasten L03

Kasten: L03
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
RP80i1280 AH (c20)700 A (EN)31717517501more
product image Starter Battery intAct Race-Power RP80

RP80

Japan-Code:{jpn}

RP80

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:80 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:700 A (EN)
Size:317 x 175 x 175 mm
Schema Batteriekasten LB4

Kasten: LB4
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet
RP95i1295 AH (c20)800 A (EN)35317519001more
product image Starter Battery intAct Race-Power RP95

RP95

Japan-Code:{jpn}

RP95

Position of Terminal:0
Schema Schaltung 0
Volt:12
Terminal:1
Schema Endpol 1Schema Endpol 1
Capacity:95 AH (c20)
Base plate:B13
Schema Bodenleiste B13Schema Bodenleiste B13
Cold Cranking Ampere:800 A (EN)
Size:353 x 175 x 190 mm
Schema Batteriekasten L05

Kasten: L05
Where can I buy this battery?

Dealer online shop

Buy online

Locally

Dealer locator
Download datasheet

Accessories
Charger

DEFA SmartCharge

Compact design for convenient charging of 12 volt batteries.


See product

Fronius Acctiva


Charge starter batteries professionally and supply consumers and on-board electronics.


See product
WHAT IS A WET BATTERY?
DOUBLE LID WITH LABYRINTH
LOW-MAINTENANCE
MAINTENANCE FREE
Checking the battery step by step
There are many reasons for weakening or failing batteries. An important step in tracking them down is to measure the voltage with a battery tester. Here's how: 1. preparation Disconnect the battery from the vehicle, if possible remove it. Tips on how …
What do discoloured plugs mean?
A brown-reddish discoloration of the plugs indicates an overcharging of the battery and a fault in the charging system. Tip: Your workshop can check whether your charge controller is working properly. Tip: Check the function and characteristics of your …
Batteries without vent hose
Only conventional, wet batteries need a vent hose, because they gas strongly during operation. The resulting steam can escape through the openings in the plugs. To prevent the vapour from damaging the vehicle, conventional batteries are vented to the …
Pay attention to the state of charge
We recommend: Check the charge level every 2 - 3 months if ... ... the vehicle is often left unused. ... you drive a lot of short distances. ... many consumers are installed. ... it is cold. ... in start-stop systems the engine does not switch off as …
Installing the starter battery or motorcycle battery
First connect the positive cable (usually red) to the positive terminal of the battery. Then connect the negative cable (usually black) to the negative terminal of the battery. If you install a start-stop battery, you must then register the battery in the vehicle system.
Every battery ages
With each charge/discharge process (cycle), active material is inevitably lost and the battery's performance declines. Once it has fallen to the point where it can no longer fulfil its purpose - e.g. start the vehicle, supply the consumers or drive the …
Our absolutely maintenance-free motorcycle batteries
intAct Bike-Power AGM, intAct Bike-Power SLA, intAct Bike-Power GEL, intAct Bike-Power HVT and intAct Bike-Power GEL HVT-HD are valve regulated lead-acid batteries or VRLA batteries (VRLA=Valve Regulated Lead-Acid). VRLA batteries produce much less gas …
What does maintenance-free mean?
In maintenance-free batteries, the electrolyte is in liquid form. They are usually closed at the factory, often with a double or labyrinth lid in which any gases produced condense and remain in the battery. In normal operation, maintenance-free ones do …
How does a melted pole occur?
A melted pole is caused by a short circuit when the battery polarity is reversed during bridging or when the poles are connected by a tool or other object. Tip: Take care when handling batteries. Learn more about short circuit and how to avoid it.
Cleanliness pays off
To ensure proper battery function, it makes sense to keep the battery surface clean and dry. Greasy or silicone-containing dirt on the lid can hinder the flow of current. Moisture on the battery can cause a short circuit in the worst case.

What is a starter battery?

A battery that is charged by the alternator and starts the vehicle. For this purpose, the starter motor requires a lot of current for a short time. In addition to the cold start capacity (CCA), which indicates how much current the battery can ideally supply, the properties of a battery influence how reliably it can provide this starting power. A battery with very good charging properties recharges more quickly, for example, which benefits vehicles in city traffic in particular. It also supplies the consumers in vehicles without an additional back-up battery or supply battery. The more electrical consumers are installed at the factory or retrofitted, the more capacity is required to supply them when the vehicle is idling or at an engine stop and still reliably restart the vehicle.

Commissioning

A battery that is not fully charged when installed will not reach its full capacity in the future and will have a significantly shortened service life.

Even factory-filled and charged batteries can lose charge during storage. We recommend that you also fully charge them before installation.

You can find out how to do this in our step-by-step guide to charging your battery.

Maintenance and Care

In maintenance-free batteries, the electrolyte is in liquid form. They are usually closed at the factory, often with a double or labyrinth lid in which any gases produced condense and remain in the battery. In normal operation, maintenance-free ones do not lose any liquid. They cannot be opened, refilling is not possible and not necessary.

For which applications is the intAct Race-Power suitable?

Symbol carcar
car, passenger car, cars, automobiles, vans, panel van
Symbol TractorsTractors
For tractors, tractors, axle tractors, tractors, bullodg, tractor tractors and implement carriers.
Symbol Construction machineryConstruction machinery
Compatible with construction machinery such as wheel loaders, tracked loaders, excavators and graders.
Symbol sitting lawn mowerssitting lawn mowers
sitting lawn mowers, lawn tractors